西门子V90电机1FL6066-1AC61-2AA1 西门子 购买指南
价格:188.00起
Complete motion control solutions from Siemens – SINAMICS V20 and SIMATIC
Siemens offers comprehensive solutions from a single source for general motion control applications with a selection of different SINAMICS application examples:
?Ready-to-run application examples, including wiring diagrams, parameter descriptions
?Sample configurations for connecting SINAMICS with SIMATIC, including hardware, software and wiring examples, installation instructions for the supplied S7 project, drive parameterization, and HMI sample projects- Correctly configured project, ready for operation
- Optimal leveraging of TIA advantages
Integrated energy flow monitoring
?Energy consumption and savings are monitored without the need for power measurement equipment- Intuitive values of power consumption and savings without additional investments for measurement equipment
- Values can be shown as kWh, CO2 or as a currency
Cost-savings for low-overload applications with SINAMICS V20 converters, frame size FSE
SINAMICS V20 frame size FSE converters feature two different load cycles:
?Low overload (LO): 110 % × IL 2) for 60 s (cycle time: 300 s)
?High overload (HO): 150 % × IH 3) for 60 s (cycle time: 300 s)
With the low-overload cycle, the converter can reach a higher output current and power.
A smaller converter can be used. Optimally designed for variable applications:
?Low overload for applications with a low dynamic response (continuous duty)
?High overload for applications with a high dynamic response (cyclic duty)
Accessories
1
SINAMICS V20 Smart Access
Wireless commissioning, operation, and diagnostics with mobile device or laptop using web server module
2
SINAMICS V20 BOP
?Same function as the integrated BOP (Basic Operator Panel)
?Can also be used for remote mounting
?Values and setpoints are changed by rotating the wheel
?For distributed mounting with IP54 and UL Type 1 enclosure rating
3
SINAMICS V20 BOP Interface
?Connection between converter and BOP
?RJ45 interface is compatible with standard network cable
4
Standard network cable
?Cable not included in delivery
?You can use any standard network cable with standard RJ45 connector
5
SINAMICS V20 Parameter Loader
?Up to 100 parameter sets with parameter settings can be written from the memory card to the converter, or saved from the converter to the memory card
?The converter does not have to be connected to the line supply
6
SINAMICS SD card
?Memory card, 512 MB
?Standard SD cards up to 32 GB are supported
7
SINAMICS V20 I/O Extension Module
?Expansion of the 400 V converters with two digital inputs and two digital outputs (relay outputs)
8
Line filter
Improved EMC characteristics
9
Line reactor
?Reduces the harmonic current
?Improves the power factor
?Recommended if input current (rms value) is higher than the rated current of the converter
10
SINAMICS V20 Braking Module
?Shortens the deceleration ramp time
?Suitable for 230 V 1 AC and 400 V 3 AC
?Adjustable duty cycle from 5 % to 100 %
?For frame sizes FSAA, FSAB, FSAC, FSA, FSB and FSC
?FSD and FSE already have an integrated braking unit
11
Braking resistor
?Dissipates regenerative energy as heat
?5 % duty cycle as default setting
12
Output reactor
For longer motor cable
?230 V 1 AC: 200 m (shielded and unshielded)
?400 V 3 AC:- for frame sizes FSA to FSD: 150 m (shielded and unshielded)
- for frame size FSE: 200/300 m (shielded/unshielded)
13
Shield connection kit
?Shield connection
?Strain relief
14
Standard fuse
Recommended fuse corresponding to the IEC/UL standard
15
Circuit breaker
Recommended circuit breaker corresponding to the IEC/UL standard
-/gbadicf/-