


价格:面议
0
联系人:王赤武
电话:
地址:中国广东广州市番禺南村镇兴业大道罗边村金边(禁止一切代开发票、网站推广的电话或传真)
产品规格:DH4,DB4-AA.DA.AV.DV
产品数量:20000000000000000000000 个
包装说明:**
关 键 词:DB4智能数显电流电压
发布时间:2007-12-07
DB4智能数显电流电压表 特点 ◎ 上下限报警继电器输出 ◎ 红色高亮数码管14.2mmH ◎ 输入0-**(电流互感器)可在0-9999间调整满刻度 ◎ 输入75 mV(电流分流器)可在100-9999间调整满刻度 ◎ 光电隔离模拟4-20mA变送输出 | VOLTAGE AND AMPERE METER >> 4 DIGIT VOL AND AMP METER >> DB4 DIGIT VOL AND AMP METER FEATURES 1.HI&LO Setpoint compare. 2.Bright LED 14.2mmH(red) 3.Input 0-**(Current Transformer)can adjust fullscale 0-9999,Input 0-75mV(Shunt Resistor) can adjust fullscale 100-9999. 4.Isolation of photoelectric for analog output 4-20mA 1. ORDERING CODE 2. AC VOLTAGE MEASUREMENT Model Code Range Resolution Input Impedance Accuracy Input Protection DB4(I)-PAV10 0-9.999V 1mV ≤2MΩ ±0.5%F.S±2Digit ≤750V DB4(I)-PAV100 0-99.99V 10mV ≤2MΩ ±0.5%F.S±2Digit ≤750V DB4(I)-PAV600 0-600.0V 100mV ≤2MΩ ±0.5%F.S±2Digit ≤750V 3. AC CURRENT MEASUREMENT Model Code Range Resolution Accuracy Input Protection DB4(I)-PAA0.2 0-200.0mA 100uA ±0.5%F.S±2Digit ≤1A DB4(I)-PAA2 0-2.000A 1mA ±0.5%F.S±2Digit ≤** DB4(I)-PAA5 0-5.000A 10mA ±0.5%F.S±2Digit ≤7A DB4(I)-PAA20 CT input 20A:** 10mA ±0.5%F.S±21Digit 1.2Per.F.S DB4(I)-PAA50 CT input 50A:** 100mA ±0.5%F.S±2Digit 1.2Per.F.S 4. DC VOLTAGE MEASUREMENT Model Code Range MAX.Resolution Input Impedance Accuracy Input Protection DB4(I)-PDV0.1 0-99.99mV 10uV ≤2MΩ ±0.5%F.S±1Digit ≤20V DB4(I)-PDV10 0-9.999V 1mV ≤2MΩ ±0.5%F.S±1Digit ≤750V DB4(I)-PDV100 0-99.99V 10 mV ≤2MΩ ±0.5%F.S±1Digit ≤750V DB4(I)-PDV600 0-600.0V 100mV ≤2MΩ ±0.5%F.S±1Digit ≤750V 5. DC CURRENT MEASUREMENT Model Code Range MAX.Resolution Input Impedance Accuracy Input Protection DB4(I)-PDA 0-±200.0mA 100uA ≤1Ω ±0.5%F.S±1Digit ≤1A DB4(I)-PDA2 0-±2.000A 1mA ≤0.1Ω ±0.5%F.S±1Digit ≤** DB4(I)-PDA5 0-±5.000A 1mA ≤0.05Ω ±0.5%F.S±1Digit ≤7A DB4(I)-PDA20 Shut Resistor 20A:75mV 由用户配置的分流器确定 ±0.5%F.S±1Digit 1.2Per.F.S DB4(I)-PDA50 Shut Resistor 50A:75mV 由用户配置的分流器确定 ±0.5%F.S±1Digit 1.2Per.F.S 1)If you need excition 4~20mA Analog output meter, Please you need with "I" in forward meter. Example, DB3-AV20 isn't with 4~20mA Analog supply output, DB3I-AV20 is with 4~20mA Analog supply output. The other models are the same. 2)Attention please:With AC C.T of the second ampere is ** that input current are bigger than **.And AC P.T. of the voltage second is 100V,if input voltage are higher than 1000V. 3)Attention please: With DC Shut Resistor of the second voltage is 75mV that input current are bigger than **. 6. SPECIFICATIONS Input mode Single ended A/D converter Dual slope Sampling speed Abt.2.5sec Response time 0.25sec Dsiplay mode Red LED (14.2mmH) Analog output 4-20mA 0.5%R.D±3Digital Analog range Measuring range can adjust fullscale setting Control output HI&LO Setpoint compare(AC 2A/250V) Power supply AC110/220V 50Hz/60Hz Power consumption ≤1.5VA Dielectic Strength AC 1500V 1min Insulation Res. DC 500V≥100MΩ Frequency range 45Hz~400Hz 7. CONNECTION DIAGRAM 8. THE OUTSIDE DIMENSION 9. CAUTIONS 1.The meter must be heating 15 minutes with the power on before use. 2.Use in ambient temperatures of 0℃ to 40℃,humidifies of 85% R.H. 3.The meter alignment interval time is one year. 4.If the input ** is superimposed with high-frequency noise,use a High-pass filter in the input ** line. 5.Input wire should not be too long. If measured ** and meter is long, please use a 2-core shielded cable, and connect its outer shite to the LO side at a ** soure. 6.If the digit meter relay is not used for a long time. Please counect power supply once every three months, not less than 4 hours each time.