5072PR, 5073PR, 5077PR 5072PR手动控制超声脉冲发生器接收器既可用于常规应用,又可用于高频应用。用于一般检测的理想配置是35 MHz(-3 dB)带宽和尖脉冲发生器。 优化的宽带激励会产生极佳的时域恢复效果,特别是在15~30 MHz的情况下。5072PR手动控制超声脉冲发生器接收器既可用于常规应用,又可用于高频应用。用于一般检测的理想配置是35 MHz(-3 dB)带宽和尖脉冲发生器。 优化的宽带激励会产生极佳的时域恢复效果,特别是在15~30 MHz的情况下。
5072PR, 5073PR, 5077PR
The 5072PR, 5037PR, and 5077PR manually controlled ultrasonic pulser-receivers are for both conventional and high frequency applications
These affordable and reliable manually controlled pulser-receivers provide the perfect building blocks for both conventional and high frequency applications. Each instrument is designed for superior low noise receiver response and high performance pulser control. | |
Features & Benefits | |
• Three models provide optimization for both conventional and high frequency applications | |
Three Models To Fit Your Testing Needs | |
Model 5072PR: 35 MHz (-3 dB) ultrasonic bandwidth and spike pulser is ideal for general testing. The impulse pulser provides optimal broadband excitation resulting in superior time domain recovery especially at higher frequencies (between 15-30 MHz). | |
Ultrasonic Pulser-Receivers | |
Pulser-receivers employed with ultrasonic transducers and an analog or digital oscilloscope are the prime building blocks of any ultrasonic test system. Square wave excitation is especially useful in applications involving the testing of thick or highly attenuating materials with low frequency transducers, typically improving both penetration capability and signal-to-noise ratio. The Model 5077PR provides square wave excitation with a fast pulse rise and fall time. The pulse voltage and pulse width are adjusted directly to provide precise control over pulse shape. By tuning the period (pulse width) of the square wave to half that of the transducer center frequency, pulse energy to the transducer at its natural resonant frequency is increased. This can result in an increase in signal amplitude as great as 12 dB or more as compared with spike pulsers using the same voltage setting. The effect is especially pronounced with transducers of 5 MHz and lower frequency. | |
Specifications* | |
PULSER 5072PR 5073PR 5077PR Pulse Type (main bang):Negative Negative Impulse Negative Square Wave Rise Time (10% to 90%):Typically 5 ns, 10 ns max Typically <2 ns Typically <10 ns, 20 ns max (rise and fall time) Available Pulse Voltage: (no load) -360 V -180 V Select -400 V, -300 V, -200 V, -100 V Available Pulse Energy:13, 26, 52, or 104 µjoules 2, 4, 8, or 16 µjoules N/A Damping:Select 15, 17, 20, 25, 36, 50, 100, or 500 ohms 12, 14, 17, 20, 25, 33, 50, or 100 ohms N/A Pulse Width:N/A N/A 10 preset fixed widths: 15-20,10, 7.5, 5.0-6.0, 3.5-4.0, 2-2.25, 1.0, 0.5, 0.25, 0.1 MHz. Variable +/-25% fine vernier tuning for each width. Mode: Pulse Echo or Thru-Transmission Isolation (53 dB min):Typically 62 dB at 10 MHz Typically 62 dB at 50 MHz Typically 62 dB at 10 MHz Pulse Repetition Rate: (Internal)100, 200, 500, 1000, 2000, or 5000 Hz 200, 500, 1000, 2000, 5000, 10000, or 20000 Hz 100, 200, 500, 1000, 2000, 5000 Hz, except that maximum PRF is limited to: 2000 Hz FOR 0.5 MHz tranducers, 1000 MHz for 0.25 MHz transducers, and 50 Hz for 0.1 MHz transducers. Pulse Repetition Rate:0-6 kHz (External) 0-10 kHz 0-5 kHz (observe limitations of PRF versus pulse width) Synch Output Pulse:3 V into 50 ohms External Trigger Input: (in series with 10 Kohms)2.4 V into 1000 PF 200 ns minimum pulse width 2.4 V into 1000 PF 200 ns minimum pulse width 2.4 V into 1000 PF 50 ns minimum pulse width RECEIVER5072PR 5073PR 5077PR Maximum Bandwidth: (-3 dB, RL=50 ohms)1 kHz - 35 MHz 1 kHz - 75 MHz 1 kHz - 35 MHz Voltage Gain:0-59, 1 dB steps (RL=50 ohms) 0-39, 1 dB steps (RL=50 ohms) 0-59, 1 dB steps (RL=50 ohms) Phase: inverting or non-inverting (internal switch) Attenuator Range:0-59, 1 dB steps (RL=50 ohms) 0-49, 1 dB steps (RL=50 ohms) 0-49, 1 dB steps (RL=50 ohms) High Pass Filter:1 kHz (out) or 1 MHz 1 kHz (out) or 5 MHz 1 kHz (out) or 1 MHz Low Pass Filter:35 MHz (out) or 10 MHz 75 MHz (out) or 20 MHz 35 MHz (out) or 10 MHz Noise:70 µV pk-pk typical, referred to input, BW=35 MHz 200 µV pk-pk typical, referred to input, BW=75 MHz 70 µV pk-pk typical, referred to input, BW=35 MHz Max Signal Output: +/-1V pk., terminated in 50 ohms Input Resistance: (Thru-Transmission)500 ohms linear range 100 ohms > linear range 100 ohms linear range 50 ohms at levels > linear range 500 ohms Output Impedance:50 ohms 50 ohms 50 ohms Maximum Input Power:400 mW 400 mW 500 mW UNIT 5072PR,5073PR,5077PR Input/Output:External Trigger In, Sync Out, RF Out, T/R and R: All BNC female connectors Power Main Requirements:100/120/220/240 VAC, 50/60 Hz Operating Temperature:0-50°C Size and Weight:7" W x 3.5" H x 9.1" D (178 mm x 89 mm x 232 mm); 5 lbs (2.3 kg)
| |
ORDERING INFORMATION: Each model is shipped with a power cord and operator manual. Transducers and cables are sold separately. *All specifications are subject to change without notice. |