价格:16600起
0
联系人:
电话:
地址:
HV-P60
High-voltage waveforms of up to DC 60 kV, pulse 80 kV measured by oscilloscope
Wide bandwidth, DC to 50 MHz
Maintenance-free, due to use of silicon rubber - guarantees stable withstand voltage
SpecificationsMaximum input voltageDC 60 kV or AC peak*
Single-shot pulse of 80 kV, standard pulse waveBandwidthDC to 50 MHz, within -3 dBRise time7 ns or less (for probes only)Input RC1000 MW ±5% //5 pF ±2 pFAttenuation2000:1 ±5%Cable lengthApprox. 4 mConnectorBNC typeUsed forOscilloscope with input RC: 1 MW, 15 to 50 pFSizeApprox. 88 mm (ø) x 338 mm (L)WeightApprox. 3.5 kg (including accessories)AccessoriesMatching box, clamp, probe tip, ground lead, adjusting screwdriver, accessory bagOptions
High-voltage probe stand SK-301 (produced upon order)
The SK-301 can be used with both the HV-P60 and the HV-P30. It is attached by turning the probe bracket upside down (for HV-P60/HV-P30).
* The P-P voltage drops if the CW is 100 kHz or greater.
This is a passive probe that measures high-voltage waveforms by connecting to an oscilloscope, and has the following characteristics: the bandwidth is DC to 50 MHz, the maximum input is DC 60 kV, and the attenuation is 2000:1.
Characteristic curve
Frequency(Sine Wave)
Maximum Input Voltage and Frequency (Sine Wave) [HV-P60]
●HV-P30