价格:电议起
深圳银通电子仪器有限公司
联系人:万常家
电话:15889559273
地址:深圳市福田区振华路海外装饰大厦
网络分析仪Agilent 8711B Agilent 8711B and 8712B, 300 kHz to 1.3 GHz Agilent 8713B and 8714B, 300 kHz to 3 GHz RF Economy Network Analyzers Configuration Guide nalyzer, 300 kHz to 1.3 GHz ? Agilent 8712B vector network analyzer, 300 kHz to 1.3 GHz ? Agilent 8713B scalar network analyzer, 300 kHz to 3 GHz ?Agilent 8714B vector network analyzer, 300 kHz to 3 GHz Options ? 75 ohms system impedance, Option 1EC Converts to 75 ohm system impedance and substitutes 75 ohm Type-N connectors. Substitutes 75 ohm test port cable and demonstration filter. Use with 75 ohm calibration kits and accessories. ? AM delay for 50 ohm systems, Option 1DA ? AM delay for 75 ohm systems, Option 1DB (Option 1EC must also be ordered with 75 ohm systems) Adds amplitude modulation group delay capability to measure group delay in frequency-translation devices such as tuners and receivers. Includes two external broadband detectors and a power splitter. Not recommended for devices with limiting circuits, saturated amplifiers or automatic gain control. For nonfrequency translation devices the vector network analyzers 8712B or 8714B offer lower noise and better accuracy when measuring group delay. ? HP Instrument BASIC (IBASIC) Option 1C2 IBASIC is a subset of BASIC for creating and executing test programs inside the network analyzer, including keystroke capture and one-button macros, without the need for an external controller. Includes Instrument BASIC User’s Handbook (part number 08712-90005) and IBASIC example program disk (part number 08712-10003). ? Option 100 fault location and structural return loss Full cable characterization in one package. Fault location includes convenience features unavailable in TDRs, including multi-bump, cable calibration, and cable loss measurements. Structural return loss, which is the return loss resulting from many small, equally spaced discontinuities, is easily and accurately measured. A user manual and instructional video tape are included. Agilent 8711B and 8712B, 300 kHz to 1.3 GHz Agilent 8713B and 8714B, 300 kHz to 3 GHz RF Economy Network Analyzers Configuration Guide 2 ? 60 dB step attenuator, Option 1E1 Extends output power range down to –60 dBm. ? Extra 50 ohm cable and Type-N (f-f) adapter, Option AFN ? Extra 75 ohm cable and Type-N (f-f) adapter, Option AFP ? Option AF4 This option deletes the Type-N cable and substitutes two N-to-BNC adapters and a BNC cable. ? Keyboard, Option 1CL Adds mini-DIN interface keyboard (part number C1405B, Option ABA), cable, and mini-DIN to DIN adapter (part number C1405-60015) to enhance IBASIC editing and instrument control capability. Keyboard overlay (part number 08712-80004) is supplied with every instrument. ? Rack mount kit, Option 1CM ? Performance test software, Option 1FP Special Options Special options are available for unique applications. Examples include multiport and reversing test sets. Contact your Agilent representative for more information. Documentation ? Deletes manual set, Option 0B0 ? Deletes service guide, Option AVB ? Deletes programming guide, Option AV7 ? Adds Agilent 8711B, 8713B manual set, Option 0B1; Also available as part number 08713-90001. ? Adds Agilent 8712B, 8714B manual set, Option 0B1; Also available as part number 08712-90001. Localization Options These options provide a localized user’s guide at no extra charge. They include information on installation, instrument functions, optimized measurements, and calibration. ? Taiwanese User’s Guide, Option AB0; Also available as part number 08712-90012. ? Korean User’s Guide, Option AB1; Also available as part number 08712-90014. ? Chinese User’s Guide, Option AB2; Also available as part number 08712-90015. ? German User’s Guide, Option ABD; Also available as part number 08712-90010. ? Spanish User’s Guide, Option ABE; Also available as part number 08712-90017. ? French User’s Guide, Option ABF; Also available as part number 08712-90009. ? Japanese User’s Guide, Option ABJ; Also available as part number 08712-90008. ? Italian User’s Guide, Option ABZ; Also available as part number 08712-90011. Warranties One-year on-site service warranty is standard at no extra charge. Where on-site service is not available, one-year return-to-Agilent service is provided. Customers may convert the standard one-year on-site warranty to a three-year return-to-Agilent warranty at the time of purchase. ? Converts one-year on-site warranty to three-year return-to-Agilent warranty, Option W08 ? Two additional years of on-site service, Option W31 Total of 3 years on-site support (where available); not available with Option W08. ? Four additional years of on-site service, Option W51 Total of 5 years on-site support (where available); not available with Option W08. ? Commercial calibration certificate with test data, Option UK6 Can be ordered at time of original purchase. Measurement Accessories Accessories are available in these connector types: 3.5 mm, 50 ohm Type-N, BNC, 75 ohm Type-N, and Type-F. A calibration kit to improve measurement accuracy is recommended for each type of connector being measured. A complete line of RF accessories can be found in the Agilent Microwave Accessories Catalog, literature number 5091-4269E. 50 Ohm Accessories ? Type-N precision calibration kit, Agilent 85032B 50 ohm Type-N kit includes fixed terminations, open circuits, and short circuits in both connector sexes. Recommend deleting the two phasematched 7 mm to Type-N adapters for both connector sexes female and male. ? Option 001 Deletes 7 mm to Type-N phase-matched adapters ? Type-N economy calibration kit, Agilent 85032E Standards include fixed termination and opencircuit/ short-circuit combination in Type-N (m) only. ? 3.5 mm precision calibration kit, Agilent 85033D 50 ohm 3.5 mm calibration standards for devices with 3.5 mm and SMA connectors. Includes fixed terminations, open circuits and short circuits in both sexes. Includes two pair of phasematched 7 mm to 3.5 mm adapters for both sexes. Recommend deleting 7 mm adapters and ordering 11878A Type-N to 3.5 mm adapter kit.