价格:0.00起
惠州市瑞诚检测技术服务有限公司
联系人:李益诚
电话:15583666183
地址:广东省深圳市龙华区大浪街道新石社区石龙仔路14号美宝和工业园1栋101
1*4面板灯DLC认证,面板灯DLC认证,条形灯DLC认证,LED灯管DLC认证,加油站灯DLC认证,停车场灯DLC认证,洗墙灯DLC认证,工矿灯DLC认证,泛光灯DLC认证,面板灯DLC认证,投光灯DLC认证,路灯DLC认证,壁灯DLC认证,景观灯DLC认证,2*2面板灯DLC认证新增了如下三种认证产品类别:1、新增-调色产品Color Tunable Product;2、新增-现场可调节产品 Field-Adjustable Product;3、新增-3英尺、8英尺灯管及2G11灯头替换灯管 3ft、8ft、2G11 Linear Replacement lamp。DLC认证申请需要提供的资料:1.测试报告(LM79报告+温升报告ISTMT);2.申请DLC认证产品必须提供安规报告(ETL或UL的报告);3.LM80报告;4.灯珠产品规格书;5.5年质保声明(有模板)DLC认证流程:1.提供申请资料;2.提供样品测试;3.出报告;4.提交报告审核;5.初审;6.付款;7.复审;8.挂网DLC认证周期:3-4周DLC认证:测试费+注册费测试费:根据产品评估注册:高级版本:1000USD 规费普通版本:500USD 规费申请:单一型号申请/功DLC V5.0 草案技术要求1.LED灯具光效的提升。此次更新只针对普通级别的光效提升。General Application Current V4.4 Requirements V5.0 Draft Requirements RationaleTroffers 100 lm/W 105 lm/W ≈5% efficacy increaseLinear Ambient 105 lm/W 110 lm/W Outdoor-Low Output 90 lm/W 100 lm/W ≈10% efficacy increaseOutdoor-Mid Output 95 lm/W 105 lm/W Outdoor-High Output 100 lm/W 110 lm/W Outdoor-Very High Output 100 lm/W 110 lm/W Linear Replacement Lamps and 2G11 Lamps 110 lm/W(bare lamp) 120 lm/W(bare lamp) ≈10% efficacy increaseFour-Pin CFL Replacement Lamps 75 lm/W(bare lamp) 85 lm/W(bare lamp) Mogul Screw-Base (E39) Replacements for HID Lamps 90-120 lm/W(In-luminaire) High Bay 105 lm/W 120 lm/W Considerable≈15% efficacy increaseCase Lighting 80 lm/W 95 lm/W High≈20% efficacy increase.Interior Directional 65 lm/W 80 lm/W 2.光的品质1) 光谱图以下为5000K色温的4种不同LED灯珠光谱图 2) 颜色要求Metric or/and Data Set Current V4.4 Requirements V5.0 Draft Requirements Method of Measurement/Evaluation Standard Premium Tier 2 Tier 1 Chromaticity(CCT & Duv) 依据ANSIC78.377-2015的7-step 依据ANSIC78.377-2019的7-step享受DLC V4.4津贴 依据ANSIC78.377-2019的4-step 享受TBD津贴 IES LM-79-08ANSI C78.377-2019Consistency (of Chromaticity) N/A 3个样品测试<0.006(CIE 1976) 3个样品测试<0.003(CIE 1976) IES LM-79-08ANSI C78.377-2019Color Rendering* CRI (CIE 13.3-1995):Ra≥80 (indoor)Ra≥65 (outdoor)Ra≥70 (high bay) 满足下列任一标准,并提供报告ANSI/IES TM-30-18:• IES Rf≥70• IES Rg≥89• -12%≤IES Rcs,h1≤+23%CIE 13.3-1995:• Ra≥80 and R9≥0 满足下列任一标准,并提供报告ANSI/IES TM-30-18:• IES Rf≥78• IES Rg≥95• -1%≤IES Rcs,h1≤+15%CIE 13.3-1995:• Ra≥90 and R9≥50享受TBD津贴 IES LM-79-08(ANSI/IES TM-30-18 Full Report and CIE 13.3-1995 complete Color Rendering Index Detail)Spectral Power Distribution N/A 需报告380-780nm内每1nm的增量 IES TM-27-14, and/orANSI/IES TM-33-18Color Maintenance* N/A Δu'v'≤0.004 Δu'v'≤0.002 ANSI/IES LM-80-15, and/or IES LM-84-14Angular Color Uniformity N/A 可选,不强制要求 可选,不强制要求 IES LM-79-08:DLC V4.4 未对R9做任何要求,而V5.0明确要求R9≥0;:颜色维持率可依据LM-80来推断是否满足V 5.0要求3) 健康方面Metric and/or Data Set Current V4.4 Requirements V5.0 Draft Requirements Method of EvaluationSpectral Power Distribution N/A 需报告380-780nm内每1nm的增量 IES TM-27-14, and/orANSI/IES TM-33-18Melanopic Flux* N/A 需报告 As per CIE S 026/E:2019M/P Ratio* N/A 需报告 As per Lucas et al., 2014, and WELL v2, Appendix L1Melanopic Daylight (D65) Efficacy Ratio * N/A 需报告 As per CIE S 026/E:2019:虽然这些性能数据可以在报告上体现,但终的影响取决于设计和现场条件。这个与人体视网膜感光和褪黑色素相关,待探讨?4) 光分布A. 所有产品都需要有IES文件;B. 除Flood and Spot Luminaires外,其余产品都需要报告BUG值。报告形式为B2 U0 G2;C. Flood and Spot Luminaires and Interior Directional Luminaires须报告Beam Angle和Field angle值。5) 眩光Metric and/or Data Set Current V4.4 Requirements V5.0 Draft Requirements Method of Evaluation Threshold Reported Listing .ies file .ies file for each optic variation None ies files for each variation N/A IES LM-79-08,ANSI/IES LM-63-02(R2008) and/or ANSI/IES TM-33-18Unified Glare Rating (UGR)Applicable to indoor luminaires and indoor retrofit kits only No related requirement None Uncorrected UGR Table and Corrected UGR Table Designation of glare potential:• Low *• Medium• High(to be defined in a later draft) Uncorrected UGR and corrected UGR tables generated using luminaire photometric data, per CIE 117-1995 and CIE 190-2010Backlight, Uplight, and Glare (BUG)Applicable to outdoor luminaires and outdoor retrofit kits only No related requirement None BUG Rating G rating (BU listed as part of Distribution policy) BUG rating generated per IES TM-15-11 and Addendum A for IES TM-15-11 using luminaire photometric data:低等级眩光产品享受TBD津贴。6) 频闪Metric Current V4.4 Require-ments V5.0 Draft Requirements Method of Evaluation Threshold Reported Tier 1 Tier 2 Short Term Flicker (Pst) n/a ≤1.0 at ** and 20% light output Pst at **, 20%, and minimum fraction of light output ANSI/IES LM-xx-19 Approved Method: Measuring Optical Waveforms for use in Temporal LDLC申请需要准备的资料:1、DLC账号和密码2、LM-79 report3、IES File4、ISTMT report 高级版本所测试的电源Tc点温度不能**电源规格书50000H使用时的低温度。5、产品规格书 主要体现电参数和光学参数,其他的可适当增加。6、LM-80 report 根据递交的版本不同,所需要的LM-80也不同。普通版本只需满足L70>50000H,而高级除了需满足L70>50000H,还需满足L90>36000H。7、灯珠规格书8、5年质保申明9、安全证书(UL证书、ETL证书或者其他安全证书)10、安装说明书11、需提供以下内容: CompanyBrand NameContact NamePhoneEmailWebsite除了以上资料外,还需要提供其他资料。关于更多DLC认证详情内容,欢迎来电咨询!惠州市瑞诚检测技术服务有限公司立足于广东,面向国际贸易市场。专业提供安全和能效检测和国际认证服务。目前贝岭在深圳设有国际优秀安规实验室,Energystar能效检测实验室和服务中心。检测认证涉及的范围很广,音、视频类产品,灯具类产品,玩具类产品,机械类产品以及电动工具等产品,每个国家都有自己的一些认证标准,我国如3C,CQC;欧盟CE、GS、R&TTE、E-mark、e-mark、ERP;美国FCC、UL、ETL、CEC、DLC、能源之星、Energy Star;加拿大ICES、CSA;澳洲C-tick、A-tick、SAA、MEPS;日本VCCI、PSE、S-mark、MIC;中国CCC、CQC;其他CB、GOST、NTRA、ROHS、REACH、PAHs、EN71等测试和认证。 同时,贝岭拥有专业强大的技术*,我们的工程师团队都是有专业认证经验的项目工程师,凭借他们多年的专业知识和丰富的经验为客户提供认证申请,标准咨询,专业测试,技术支持和的整改方案,做到高效、、公正、快捷!DLC 于美国东部时间2019年04月28日发布了DLC V4.2正式版标准(见附件),距离DLC V4.1标准发布仅仅不到6个月,DLC V4.2于发布当日开始生效。此次DLC标准从V4.1版本升级到V4.2版本,对绝大多数已经列名DLC的产品没有直接影响。特定类型的产品(下文详述),则必须在3个月内升级重新递交,否则产品型号将从列名清单中移除。此次标准主要变化详细如下:变化一:危险场所灯具的新测试和报告要求危险场所照明灯具可以按照可以套用的主要类别(primary use),或者特殊(specialty)类别来申请。在DLC V4.2版本中,如果制造商通过特殊类别来申请(其中包括室外壁装、广场、泛光灯、室内高棚工矿灯主要类别下,申请特殊类别危险场所照明),则必须满足额外的文件要求。该要求具体为产品通过特殊类别来申请危险场所照明认证时,必须提供满足UL844的认证符合文件,包括产品认证的等级和分类。如果产品按照已有的主要类别(primary use)来申请,不按照Specialty来申请,则不需要满足该要求。变化二:LED灯管的测试和报告要求请注意只有带灯头的LED灯管才适用DLC的LED替换灯管的要求。不带灯头的灯管被DLC视为翻新套件,不在此次讨论范围内。在旧标准中,DLC目前认可0.6米,1.2米LED灯管和U型管。在DLC V 4.2版本中,DLC将1.2米灯管要求拆分为三类具体的产品要求:◆ 1.2米LED替换T8灯管产品必须是48英寸长并使用G13灯头,任何制造商材料都必须声明替换的是T8同长度的荧光灯管。DLC不允许制造商宣称替换其他长度或直径的荧光灯管,比如一个T8的LED灯管替换T12荧光灯管,是不被允◆ 1.2米LED替换T5管产品必须是46英寸长并使用G5灯头,任何制造商材料都必须声明替换的是T5同长度的荧光灯管。DLC不允许制造商宣称替换其他长度、灯头或直径的荧光灯管。◆ 1.2米LED替换T5HO灯管产品必须是46英寸长并使用G5灯头,任何制造商材料都必须声明替换的是T5HO同长度的荧光灯管。DLC不允许制造商宣称替换其他长度、灯头或直径的荧光灯管。下表是4.2版本更新后所有灯管裸管的要求:注意:针对于Type A的T5和T5HO灯管,DLC强制要求搭配ballast factor 1.0的electronic programmed-start ballast进行测试,而且递交时的上报功率值必须是灯管和镇流器的组合功率,而不是裸灯管的功率。T5替换灯管同样也需要配灯具做灯具级别的光度测试。普通T5管测试与T8灯管没有区别。不同点在于T5HO灯管需要使用专门的外壳,而且如果是Type A/B或Dual模式1.2米T5HO灯管,则需要使用4根灯管搭配外壳测试。如果是Type C的T5HO灯管,DLC目前只认可一拖三,一拖四和一拖六三种方案。T5HO有不同的光效、光通量和光分布要求,详细见DLC V4.2版本。T8直径=T*8=1英寸=26MM,T5直径=T*5=5/8英寸=16MM,其中T是直径代码,T=1/8英寸。HO=High Output。关于更多DLC认证详情内容,欢迎来电咨询!惠州市瑞诚检测技术服务有限公司立足于广东,面向国际贸易市场。专业提供安全和能效检测和国际认证服务。目前贝岭在深圳设有国际优秀安规实验室,Energystar能效检测实验室和服务中心。检测认证涉及的范围很广,音、视频类产品,灯具类产品,玩具类产品,机械类产品以及电动工具等产品,每个国家都有自己的一些认证标准,我国如3C,CQC;欧盟CE、GS、R&TTE、E-mark、e-mark、ERP;美国FCC、UL、ETL、CEC、DLC、能源之星、Energy Star;加拿大ICES、CSA;澳洲C-tick、A-tick、SAA、MEPS;日本VCCI、PSE、S-mark、MIC;中国CCC、CQC;其他CB、GOST、NTRA、ROHS、REACH、PAHs、EN71等测试和认证。 同时,贝岭拥有专业强大的技术*,我们的工程师团队都是有专业认证经验的项目工程师,凭借他们多年的专业知识和丰富的经验为客户提供认证申请,标准咨询,专业测试,技术支持和的整改方案,做到高效、、公正、快捷!