Test on the brake with 45°C oil temperature - Empty test - Loaded test V 360 - 380 - 400 - 415 in power and torque - Cyclical test of plants tor residential use: rated tension + - 5% 20” on 80” off observation of the behaviour of technical protector. - Cyclical test of plants tor continuous use: rated tension + - 5% 13” on 32” off. Charge 1.1 rated power. - Cyclical test of removal: rated tension - 5% 5” on 10” off nr. 20 consecutive insertions. - Specifics concerning the motor shaft torque: the motor must move a maximum rated torque of 1.87 - High pressure valve setting: rated torque of 1.7 maintained tor 20” with rated tension of 0.95 - Cold motor starting linked to cog wheel: starting torque must result - 0.4 rated torque. - Long run: rated power of 1.3 for 60” with a rated tension of 0.9. Relief intervention of the thermal protector.