价格:面议
深圳市展业达鸿科技有限公司
联系人:吕先生
电话:15920060912
地址:深圳市福田区八卦四路华晟达大厦7楼5A
产品规格:
产品数量:
包装说明:
关 键 词:CIRS,008M,008M躯干体模,美国CIRS,CIRS,008M躯干体模
行 业:
发布时间:2018-02-24
美国CIRS 008M躯干体模产品简介: 美国CIRS 008M躯干体模主要用于放射疗法的测试体模 / MRI躯干体模 深圳市展业达鸿科技有限公司 联系人:吕先生 手机: Q 邮箱:@139.com 办公地址:深圳市福田区八卦四路22号华晟达大厦7楼5A The CIRS MRI-LINAC Dynamic Phantom is designed for end-to-end commissioning, machine QA for hybrid MRI-LINAC Radiation Therapy systems, and verification of gated and adaptive treatment plans. CIRS 008M provides a means to assess MRI image quality, and to test tumor localization and motion-capturing devices. The phantom can be used to acquire moving or static target images for treatment planning and verification of gated or adaptive treatment delivery. TCIRS 008M, moving rod with target and extended rigid shaft connection are MRI-safe with 1.5T magnets. Motors and motion controller electronics are located at a safe distance from the magnet to ensure MRI image quality. The MRI-LINAC Dynamic Phantom utilizes CIRS Motion Control Software to provide precise, repeatable 3D target motion. CIRS 008M approximates an average human body in size and shape. It is comprised of a plastic shell with a cylindrical thru hole to accommodate a moving rod with simulated target. The shell is filled with proprietary MRI **-generating gel that allows for quick and easy phantom set-up without liquid motion artifacts. The phantom body is suspended on non-magnetic rails that allow for coil positioning and phantom registration to the couch. 美国CIRS 008M躯干体模,CIRS 008M测试体模,CIRS 008M躯干模体 美国CIRS 008M躯干体模,CIRS 008M测试体模,CIRS 008M躯干模体 CIRS 008M contains MRI QA targets that are compatible with ACR accreditation program recommendations for: MRI image spatial distortion MRI field homogeneity Laser to ISO center coincidence The moving insert with simulated target is a sealed, cylindrical rod filled with the same MRI **-generating proprietary gel as the phantom body. The embedded MRI/CT target is made of MRI gel that provides contrast with respect to the background. This target can receive an ion chamber or other MRI-compatible dosimeters for treatment dose verification. There are laser marks machined on the outside of MRI shell body for both the MRI/CT target and MRI Distortion Grid. To facilitate MRI/CT Image fusion, there is a central fiducial aligned with the exterior laser marks, and in a known position with respect to 3D spatial distortion grid. 美国CIRS 008M躯干体模,CIRS 008M测试体模,CIRS 008M躯干模体特点: MRI-CT-LINAC Compatible 3D target motion Gated and adaptive RT plan verification End-to-end commissioning MRI QA