价格:面议
上海桂伦自动化科技有限公司
联系人:郑晓
电话:13611748727
地址:上海
产品规格:KFA6-SR2-Ex1
产品数量:100 个
包装说明:
关 键 词:安全栅
行 业:
发布时间:2010-08-19
在应用过程中,有一些信号需要相应的转换(如:危险区域的开关量/模拟量要在安全区域中得到放大/隔离;分离式的电极式液位开关的信号转换;以及电位器电阻分压信号转换为相应的电流信号等)才能进行后续的处理,因此,需要相关的二次仪表把信号转换为便于处理的数字/模拟信号。 隔离安全栅将危险区域的开关量信号(NAMUR 信号)转换/放大成继电 器的触点动作信号,可以直接驱动负载或作为开关量信号输入后级处理设备。可以和本安型的极限位置检测物位开关配套使用。 典型型号:KFD2-STC4-EX1 安全栅常用型号: KFD2-SR2.Ex1.W KFD2-SD-Ex1.48 KFD2-SR2-Ex1.W.LB KFD0-SD2-Ex1.1045 KFD2-SR-Ex1.4S.LK KFD2-SL-Ex1.48 KFD2-SRT-Ex1 KFD2-SD-Ex1.48-90A KFD2-ST-Ex1 KFD2-SL-Ex1.48-90A KFD2-ST2-Ex1.LB KFD2-SD-Ex1.17 KFD2-SOT-Ex1 KFD0-SD2-Ex1.1065 KFD2-SOT2-Ex1.LB KFD2-SD-Ex1.36 KFD2-SOT2-EX1.LB.IO KFD0-SD2-Ex1.1180 KFD2-SR2-Ex2.W KFD0-SD2-Ex2.1045 KFD2-SR2-Ex2.2S KFD2-VM-Ex1.35 KFD2-SRA-Ex4 KFD2-VD-Ex1.1560 KFD2-ST-Ex2 KFD2-SL2-EX1 KFD2-ST2-Ex2 KFD2-SL2-EX1.B KFD2-SOT-Ex2 KFD2-SL2-Ex1.LK KFD2-SOT2-Ex2.IO KFD2-SL2-Ex2 KFD2-SOT2-Ex2 KFD2-SL2-Ex2.B Switch Amplifier [EEx i] 185532 KCD2-SR-EX1.LB 1-channel, relay output 1 NO contact and lead monitoring, 24V DC 132958 KFD2-SR2.Ex1.W 1-channel, relay output 1 SPDT, 24V DC 103371 KFA5-SR2-Ex1.W 1-channel, relay output SPDT, 115 V AC, up to SIL2 (IEC 61508) 103374 KFA6-SR2-Ex1.W 1-channel, relay output SPDT, 230 V AC, up to SIL2 (IEC 61508) 132959 KFD2-SR2-Ex1.W.LB 1-channel, relay output 2 SPDT, lead monitoring, up to SIL2 (IEC 61508) 103372 KFA5-SR2-Ex1.W.LB 1-channel, relay output 2 SPDT, 115 V AC, up to SIL2 (IEC 61508) 103375 KFA6-SR2-Ex1.W.LB 1-channel, relay output 2 SPDT, 230 V AC, up to SIL2 (IEC 61508) 185533 KCD2-SR-EX2 2-channel, relay output 1 NO contact per channel, up to SIL2 (IEC 61508) 132960 KFD2-SR2-Ex2.W 2-channel, relay output 1 SPDT per channel, up to SIL2 (IEC 61508) 103370 KFA5-SR2-Ex2.W 2-channel, relay output 1 SPDT per channel, 115 V AC, up to SIL2 (IEC 61508) 103373 KFA6-SR2-Ex2.W 2-channel, relay output 1 SPDT per channel, 230 V AC, up to SIL2 (IEC 61508) 107809 KFA5-SR2-EX2.W.IR With minimum / maximum mode 115 VAC 107093 KFA6-SR2-EX2.W.IR With minimum / maximum mode 230 VAC 181284 KFD2-SR2-Ex2.2S 2-channel, relay output 2 NO contact per channel, up to SIL2 (IEC 61508) 190176 KFD2-SRA-Ex4 4-channel, 2:1 function, relay output 1 NO contact per channel 034782 KFD2-SRT-Ex1 1-channel, relay output 1SPDT and active transistor output 033928 KFD2-SR-Ex1.4S.LK 1-channel, relay output 4 NO contact and lead monitoring 188366 KFD2-DU-Ex1.D 1-channel, 1 SPDT relay output, 1 electronic output, potential free, timer function 188367 KFA5-DU-EX1.D 1-channel, 1 relay SPDT output, 1 electronic output, potential free, timer function, 115 VAC 188368 KFA6-DU-EX1.D 1-channel, 1 relay SPDT output, 1 electronic output, potential free, timer function, 230 VAC 115162 KFD2-ER-EX1.W.LB [EEx ia] 1-channel, supply power 1 ... 150 kOhm, lead monitoring, switching delay 115164 KFA5-ER-EX1.W.LB [EEx ia] 1-channel, supply power 1 ... 150 kOhm, lead monitoring, switching delay 115163 KFA6-ER-EX1.W.LB [EEx ia] 1-channel, supply power 1 ... 150 kOhm, lead monitoring, switching delay 180997 KFD2-ST2-Ex1.LB 1-channel, 2 active transistor output, lead monitoring and error message, up toSIL2 (IEC 61508) 181000 KFD2-ST2-Ex2 2-channel, 1 active transistor output per channel, up to SIL2 (IEC 61508) 181002 KFD2-SOT2-Ex1.LB 1-channel, 2 passive transistor output, lead monitoring and error message, up to SIL2 (IEC 61508) 181004 KFD2-SOT2-EX1.LB.IO 1-channel, 2 passive, galvanic isolated transistor output, lead monitoring and error message, up to SIL2 (IEC 61508) 195092 KFD2-SOT2-Ex1.N 1-channel, lead monitoring and error message, Output Namur kompatible, up to SIL2 (IEC 61508) 181005 KFD2-SOT2-Ex2 2-channel, 1 passive transistor output per channel, up to SIL2 (IEC 61508) 198029 KFA5-SOT2-Ex2 2-channel, 1 passive transistor output per channel, 115 V AC, up to SIL2 (IEC 61508) 198030 KFA6-SOT2-Ex2 2-channel, 1 passive transistor output per channel, 230 V AC, up to SIL2 (IEC 61508) 181007 KFD2-SOT2-Ex2.IO 2-channel, 1 active transistor output per channel, galvanic isolated, up to SIL2 (IEC 61508) Safety Switch Amplifiers 046903 KFD2-SH-Ex1 1-channel, relay output, safety-related up to SIL3 (IEC 61508) 035845 KFD2-SH-Ex1.T.OP 1-channel, electronic output, safety-related up to SIL3 (IEC 61508) 046904 KHA6-SH-Ex1 1-channel, relay output, safety-related up to SIL3 (IEC 61508) Frequenzy Converters 132964 KFD2-SR2-EX2.W.SM 1-channel, standstill monitor and direction of rotation detection, up to SIL2 (IEC 61508) 188379 KFD2-DWB-Ex1.D 1-channel, Rotation speed monitor, with LC display, up to SIL2 (IEC 61508) 188381 KFA5-DWB-EX1.D 1-channel, rotation speed monitor with LC display, 115 V AC, up to SIL2 (IEC 61508) 188383 KFA6-DWB-EX1.D 1-channel, Rotation speed monitor with LC display, 230 V AC, up to SIL2 (IEC 61508) 188370 KFD2-UFC-EX1.D 1-channel, Frequency to Current converter, rotation speed monitor, divider, with LC display, up to SIL2 (IEC 61508) 188372 KFU8-UFC-EX1.D 1-channel, Frequency to Current converter, rotation speed monitor, divider, with LC display, up to SIL2 (IEC 61508) 188375 KFD2-UFT-Ex2.D 1/2-channel, Frequency to Current converter, direction of rotation, synchronous run, with LC display, up to SIL2 (IEC 61508) 188377 KFU8-UFT-Ex2.D 1/2-channel, Frequency to Current converter, direction of rotation, synchronous run, with LC display, up to SIL2 (IEC 61508) Discrete Output Signals Solenoid drivers [EEx i] 133240 KFD0-SD2-Ex1.1045 1-channel, 45 mA, 10 V/full load up to SIL3 (IEC 61508) 133245 KFD0-SD2-Ex2.1045 2-channel, 45 mA, 10 V/full load up to SIL3 (IEC 61508) 185534 KCD0-SD-EX1.1245 1-channel, 45 mA, 10 V/full load up to SIL3 (IEC 61508); Housing width 12.5 mm 186183 KFD0-SD2-EX2.1245 1-channel, 45 mA, 10 V/full load up to SIL3 (IEC 61508) 133238 KFD0-SD2-Ex1.1065 1-channel, 65 mA, 10 V/full load up to SIL3 (IEC 61508) 133239 KFD0-SD2-Ex1.1180 1-channel, 80 mA, 11 V/full load up to SIL3 (IEC 61508) 133237 KFD0-SD2-Ex1.10100 1-channel, 100 mA, 10 V/full load up to SIL3 (IEC 61508) 098078 KFD2-SL2-EX1 1-channel, 24 V, 45 mA; lead monitoring via Power Rail, up to SIL2 (IEC 61508) 098088 KFD2-SL2-EX1.B 1-channel, 24 V, 45 mA, basic version, with out lead monitoring, up to SIL2 (IEC 61508) 050210 KFD2-SL2-Ex1.LK 2-channel, 24 V, 45 mA; lead monitoring, relay output, up to SIL2 (IEC 61508) 039267 KFD2-SL2-Ex2 2-channel, 24 V, 45 mA; lead monitoring via Power Rail, up to SIL2 (IEC 61508) 098089 KFD2-SL2-Ex2.B 2-channel, 24 V, 45 mA, basic version, with out lead monitoring, up to SIL2 (IEC 61508) 033925 KFD2-VM-Ex1.35 1-channel, 22,3 V, 17 mA 103076 KFD2-VM-Ex1.35.L 1-channel, 22,3 V, 17 mA; Testsocket Relay unit [EEx i] 038975 KFD0-RO-Ex2 2-channel, output [EEx i], 1 SPDT per channel Analog Input Signals Transmitter power supplies [EEx i] 185535 KCD2-STC-EX1 1-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, up to SIL2 (IEC 61508) 122580 KFD2-STC4-Ex1 1-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, up to SIL2 (IEC 61508) 122583 KFD2-STC4-Ex1-Y122583 192017 KFD2-STC4-Ex1.H 125458 KFD2-STV4-EX1-1 1-channel, 2-wire; 4 ... 20 mA / 1 ... 5 V, HART, up to SIL2 (IEC 61508) 125459 KFD2-STV4-EX1-2 1-channel, 2-wire; 4 ... 20 mA / 2 ... 10 V, HART, up to SIL2 (IEC 61508) 122581 KFD2-STC4-Ex1.2O 1-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, 2 galvanic isolated outputs, up to SIL2 (IEC 61508) 122582 KFD2-STC4-Ex1.2O-Y122582 1-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, 2 galvanic isolated outputs (current sink), up to SIL2 (IEC 61508) 192018 KFD2-STC4-Ex1.2O.H 1-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, 2 galvanic isolated outputs, higher field voltage, up to SIL2 (IEC 61508) 125457 KFD2-STV4-EX1.2O-1 1-channel, 2-wire; 4 ... 20 mA / 1 ... 5 V, HART, 2 galvanic isolated outputs, up to SIL2 (IEC 61508) 125456 KFD2-STV4-Ex1.2O-2 1-channel, 2-wire; 4 ... 20 mA / 2 ... 10 V, HART, 2 galvanic isolated outputs, up to SIL2 (IEC 61508) 042083 KFD2-STC4-Ex2 2-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, up to SIL2 (IEC 61508) 203646 KFD2-STC4-Ex2-Y203646 2-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, HART, 2 galvanic isolated outputs (current sink), up to SIL2 (IEC 61508) 072220 KFD2-STV4-EX2-1 2-channel, 2-wire; 4 ... 20 mA / 1-5 V, HART, up to SIL2 (IEC 61508) 111659 KFD2-STV4-EX2-2 2-channel, 2-wire; 4 ... 20 mA / 2 ... 10 V, HART, up to SIL2 (IEC 61508) 126986 KFD2-STC3-Ex1 1-channel, 2-wire; 4 ... 20 mA / 4 ... 20 mA, SMART 126989 KFD2-STV3-Ex1-1 1-channel, 2-wire; 4 ... 20 mA / 1-5 V, SMART 126990 KFD2-STV3-Ex1-2 1-channel, 2-wire; 4 ... 20 mA / 2 ... 10 V, SMART Transmitter power supply with trip value [EEx i] 051097 KFD2-CRG-Ex1.D 1-channel, 2-wire; 0 ... 20 mA / 0 ... 20 mA, with 2 trip outputs, Display, up to SIL2 (IEC 61508) 051099 KFU8-CRG-Ex1.D 1-channel, 2-wire 0 ... 20 mA / 0 ... 20 mA, 2 trip relay outputs, up to SIL2 (IEC 61508) Current Repeaters [EEx i] 125782 KFD0-CS-Ex1.52 1-channel, 0 ... 20 mA, input [EEx i], Accuracy 0,1% 125783 KFD0-CS-Ex2.52 2-channel, 0 ... 20 mA, input [EEx i], Accuracy 0,1% 107496 KFD0-CS-Ex1.54 1-channel, 0 ... 20 mA, input [EEx i], SMART fire detectors 107497 KFD0-CS-Ex2.54 2-channel, 0 ... 20 mA, input [EEx i], SMART fire detectors Voltage Repeaters [EEx i] 181951 KFD2-VR2-Ex1.50m 1-channel, Voltage Repeater 0- +/-50 mV 071916 KFD2-VR-Ex1.500m 1-channel, Voltage Repeater 0- +/-500 mV 116955 KFD2-VR-Ex1.12 1-channel, Voltage Repeater 0-9 V 072036 KFD2-VR-Ex1.18 1-channel, Voltage Repeater 0-12 V 072037 KFD2-VR-Ex1.19 1-channel, Voltage Repeater 0- +/ ... 10 V 117144 KFD2-VR4-EX1.26 1-channel, Voltage Repeater ... 20 - 0 V, for vibration monitor Current and voltage converter [EEx i] 043690 KFD0-CC-Ex1 1-channel, input [EEx i]: 0/4 ... 20 mA, 0/1-5 V, 0/2 ... 10 V, output: 4 ... 20 mA 122903 KFD2-WAC2-EX1.D 1-channel, for strain gauge and load cells, output 4 ... 20 mA Temperature converter and repeater [EEx i] 116917 KFD2-UT2-Ex1 1-channel, for RTDs and thermocouple, output 4 ... 20 mA 191883 KFD2-UT2-Ex1-1 1-channel, for RTDs and thermocouple, output 1-5 V 117073 KFD2-UT2-Ex2 2-channel, for RTDs and thermocouple, output 4 ... 20 mA 191887 KFD2-UT2-Ex2-1 2-channel, for RTDs and thermocouple, output 1-5 V 043691 KFD0-TR-Ex1 1-channel, RTD, loop powered 043692 KFD0-TT-Ex1 1-channel, for thermocouple, loop powered 190247 KCD2-RR-Ex1 1-channel, for Pt100: -200 °C ...+850 °C Temperature converter with trip value [EEx i] 111197 KFD2-GU-Ex1 1-channel, for current, voltage, RTDs and thermocouple input 113604 KFD2-GUT-Ex1.D 1-channel, for current, voltage, RTDs and thermocouple input, with analouge output; SIL2 (IEC 61508) 113605 KFU8-GUT-EX1.D 1-channel, current, voltage, temperature- input, 2 SPDT output, analoque output, universal supply, bis SIL2 (IEC 61508) Potentiometer and Resistor converter [EEx i] 116917 KFD2-UT2-Ex1 1-channel, for RTDs and thermocouple, output 4 ... 20 mA 191883 KFD2-UT2-Ex1-1 1-channel, for RTDs and thermocouple, output 1-5 V 117073 KFD2-UT2-Ex2 2-channel, for RTDs and thermocouple, output 4 ... 20 mA 191887 KFD2-UT2-Ex2-1 2-channel, for RTDs and thermocouple, output 1-5 V 127819 KFD2-RR-Ex1 1-channel, for Pt100: -200 °C ...+850 °C 072018 KFD2-PT2-Ex1 1-channel, potentiometer converter, 5-wire, 0 ... 10 V 72019 KFD2-PT2-Ex1-1 1-channel, potentiometer converter, 5-wire, 0 ... 5 V 72022 KFD2-PT2-Ex1-4 1-channel, potentiometer converter, 5-wire, 0 ... 20 mA 072023 KFD2-PT2-Ex1-5 1-channel, potentiometer converter, 5-wire, 4 ... 20 mA 043693 KFD0-RC-Ex1 1-channel, for resistors 0,5 ... 10 kOhm, loop powered Analog Inputs with Special Functions 198804 KFD2-HLC-EX1.D 1-channel, 2-wire; HART-communication, 3 galvanic isolated outputs 198803 KFD2-HLC-EX1.D.2W 1-channel, 2-wire; HART-communication, 3 galvanic isolated outputs, 2 Relay 198802 KFD2-HLC-EX1.D.4S 1-channel, 2-wire; HART-communication, 3 galvanic isolated outputs, 4 Relay 116923 KFD2-FF-Ex2.RS232 RS 232 Transmission, bidirectional, from/to the I.S. area 98634 KFD2-ELD-Ex16 16-channel, Ground fault detection 194658 EI-0D2-10Y-10B Intrinsically safe Ethernet Isolator 211981 DN421 1-channel, 2 wire transmitter power supply Analog Output Signals Current drivers [EEx i] 186228 KCD2-SCD-EX1 1-channel, 4 ... 20 mA / 4 ... 20 mA, SMART, lead monitoring 122033 KFD2-SCD-Ex1.LK 1-channel, 4 ... 20 mA / 4 ... 20 mA, SMART, lead monitoring 123524 KFD2-SCD2-Ex1.LK 1-channel, 4 ... 20 mA / 4 ... 20 mA, SMART, lead monitoring 123523 KFD2-CD2-EX1 1-channel, 4 ... 20 mA / 4 ... 20 mA 104204 KFD2-CD-EX1.32 1-channel, 0 ... 20 mA / 0 ... 20 mA, Standard 122397 KFD2-SCD2-EX2.LK 2-channel, 4 ... 20 mA / 4 ... 20 mA 123522 KFD2-CD2-EX2 2-channel, 4 ... 20 mA / 4 ... 20 mA 041655 KFD0-SCS-Ex1.55 1-channel, 4 ... 20 mA, SMART, for transmitters and positioners, Accuracy 0,3% 072143 KFD0-CS-Ex1.50P 1-channel, 0 ... 20 mA, output [EEx i], inverse-polarity protection, Accuracy 0,1% 072147 KFD0-CS-Ex1.51P 1-channel, 0 ... 20 mA, output [EEx i], inverse-polarity protection, Accuracy 0,1% 072150 KFD0-CS-Ex1.53 1-channel, 0 ... 20 mA, output [EEx i], Accuracy 1% 072145 KFD0-CS-Ex2.50P 2-channel, 0 ... 20 mA, output [EEx i], inverse-polarity protection, Accuracy 0,1% 072149 KFD0-CS-Ex2.51P 2-channel, 0 ... 20 mA, output [EEx i], inverse-polarity protection, Accuracy 0,1% 072152 KFD0-CS-Ex2.53 2-channel, 0 ... 20 mA, output [EEx i], Accuracy 1% Accessories 189784 KFD2-EB2.R4A.B 24 V DC / 2 A, for redundant power supplies, with bus terminal 043546 KFD2-EB2 24 V DC / 4 A 046544 KFA6-STR-1.24.500 1-channel, primary: 92 ... 265 V AC, secondary: 24 V DC / 500 mA 054270 KFA6-STR-1.24.4 1-channel, primary: 92 ... 265 V AC, secondary: 24 V DC / 4 A 119265 UPR-03 3-conductor, length: 2 m incl. DIN rail and caps, replaced UPR-02 197007 UPR-03-S 038005 UPR-05 5-conductor, length: 2 m incl. DIN rail and caps 197008 UPR-05-S 198402 UPR-I Insulation Spacer for Power Rail 38035 UPR-E 034302 K-MS Mounting socket 071901 K-CJC-BU terminal with integrated temperature sensor for cold junction compensation for thermocouple, blue, for IS 103331 KF-FKC-3G2B device connector with cage clamp contact, set of 3 pieces green, 2 pieces blue) 103334 KF-FKC-5B device connector with cage clamp contact, set of 5 pieces blue 103330 KF-FKC-5G device connector with cage clamp contact, set of 5 pieces green 181645 K-500R0%1 measurement resistor 500 Ohm 0,1 %, 204279 KCD0-LGH Dummy housing with internal marshalling and wiring area, KC-Modul 034343 KFD0-LGH Dummy housing with internal marshalling and wiring area 126984 KFD0-LGH-GN Dummy housing with internal marshalling and wiring area, green 034868 KFD0-LGH-Y34868 Dummy housing for KF boards or motherboards to hold unused cables (reserve position) 112694 F-KD-Ex2 Terminal modules with diodes for 2:1 mode of NAMUR sensors, set of 5 pieces 112693 F-KDR-Ex2 Terminal modules with diodes and 10k/1k resistor for 2:1 mode of an mechanical contact, set of 5 pieces 119114 IS01 Sensor-Simulator (NAMUR) 115147 F-MPN-1 Pickup-Namur Converter 181953 K-ADP1 PC adapter, 3,5 X 18,3 mm plug + 3,5 X 14 mm plug 188916 K-ADP-USB PC adapter: USB <--> 3,5 X 18,3 mm plug + 3,5 X 14 mm plug 195870 DTM-Collection-CD H-System Discrete Input Signals Switch Amplifier [EEx i] 121540 HID2821 1-channel, relay output 121448 HiD2822 2-channel, relay output 121451 HiD2824 4-channel, relay output 121454 HiD2842 2-channel, electronic output, up to SIL2 (IEC 61508) 121457 HiD2844 4-channel, electronic output 185536 HiC2821 1-channel, relay output 185537 HiC2822 2-channel, relay output Safety switch amplifier [EEx i] 198449 HIC2851 1-channel, Namur output Frequency converters [EEx i] 130109 HiD2891 1-channel, frequency converter with trip relay and analouge output Discrete Output Signals Solenoid driver 185538 HiC2871 1-channel, bus or loop powered, up to SIL3 121464 HiD2871 1-channel, bus or loop powered 121471 HiD2872 2-channel, bus or loop powered, up to SIL2 (IEC 61508) 121502 HiD2873 1-channel, bus powered 121505 HiD2874 2-channel, bus powered 121486 HiD2875 1-channel, bus or loop powered, Io = 93 mA 121489 HiD2876 2-channel, bus or loop powered, Io = 93 mA, up to SIL2 (IEC 61508) 121512 HiD2877 1-channel, bus powered, Io = 93 mA 121515 HiD2878 2-channel, bus powered, Io = 93 mA 121518 HiD2881 1-channel, bus or loop powered, II B output, up to SIL2 (IEC 61508) Relay unit [EEx i] 132228 HiD2862 2-channel, Relay, 1 SPDT per channel [EEx i] Analog Input Signals Transmitter power supplies [EEx i] 185539 HiC2025 1-channel, 2-Wire: 4...20 mA, SMART 121426 HiD2025 1-channel, 2-Wire: 4 ... 20 mA, SMART 121429 HiD2026 2-channel, 2-Wire: 4 ... 20 mA, SMART, up to SIL2 (IEC 61508) 121432 HiD2025SK 1-channel, 2-Wire: 4 ... 20 mA, SMART, Sink mode output 121434 HiD2026SK 2-channel, 2-Wire: 4 ... 20 mA, SMART, Sink mode output, up to SIL2 (IEC 61508) 121492 HiD2029 1-channel, 2-Wire: 4 ... 20 mA, SMART 121495 HiD2030 2-channel, 2-Wire: 4 ... 20 mA, SMART, up to SIL2 (IEC 61508) 121498 HiD2029SK 1-channel, 2-Wire: 4 ... 20 mA, SMART, Sink mode output 121500 HiD2030SK 2-channel, 2-Wire: 4 ... 20 mA, SMART, Sink mode output, up to SIL2 (IEC 61508) 185930 HiD2024 4-channel, 2-Wire: 4 ... 20 mA, SMART Current and voltage converter [EEx i] 128759 HiD2012 2-channel, Voltage/Current, SMART Temperature converter [EEx i] 121436 HiD2061 1-channel, for thermocouplers or mV inputs 121439 HiD2062 2-channel, for thermocouplers or mV inputs 121442 HiD2071 1-channel, for RTD or potentiometer converter 121445 HiD2072 2-channel, for RTD or potentiometer converter 475751 HiD2082 2-channel, universal converter for temperature Analog Output Signals Current drivers [EEx i] 186229 HiC2031 1-channel, 4...20 mA, SMART 121478 HiD2031 1-channel, 4 ... 20 mA 121480 HiD2032 2-channel, 4 ... 20 mA 121474 HiD2033 1-channel, 4 ... 20 mA 121476 HiD2034 2-channel, 4 ... 20 mA 121508 HiD2035 1-channel, 1,5 ... 50 mA 121510 HiD2036 2-channel, 1,5 ... 50 mA 121482 HiD2037 1-channel, 4 ... 20 mA, SMART 121484 HiD2038 2-channel, 4 ... 20 mA, SMART Termination Boards Termination Boards 195043 HiCTB08-UNI-SC-SC 8 Positions, screw-clamp terminals for Ex, screw-clamp terminals for Non-Ex 195044 HiCTB16-UNI-SC-SC 16 Positions, screw-clamp terminals for Ex, screw-clamp terminals for Non-Ex 195050 HiCTB08-UNI-SD37-SC 195051 HiCTB16-UNI-SD37-SC 195045 HiDTB08-UNI-SC-SC 8 Positions, screw-clamp terminals for Ex, screw-clamp terminals for Non-Ex 195046 HiDTB16-UNI-SC-SC 16 Positions, screw-clamp terminals for Ex, screw-clamp terminals for Non-Ex 195053 HIDTB08-UNI-DA16-SD37-SC 8 Positions, 16 channels, screw-clamp terminals for Ex, SUB-D for Non-Ex 195055 HIDTB08-UNI-DA32-SD37-SC 8 Positions, 32 channels, screw-clamp terminals for Ex, SUB-D for Non-Ex 195058 HIDTB16-UNI-DA32-SD37-SC 16 Positions, 32 channels, screw-clamp terminals for Ex, SUB-D for Non-Ex 195054 HIDTB16-UNI-DA64-SD37-SC 16 Positions, 64 channels, screw-clamp terminals for Ex, SUB-D for Non-Ex Accessories 195047 HIATB01-FAULT-01 Fault Monitor Board 195048 HIATB01-HART-2X16 HART Communication Board, 2x16 195049 HIATB01-HART-4X8 HART Communication Board, 4x8 206726 HIALC-HiCTB-SET-108 Label Carrier Set 206727 HIALC-HiDTB-SET-150 Label Carrier Set 206079 HIACA-UNI-FLK34-FLK34-0M5 HART Interface Cable 0,5 m 206080 HIACA-UNI-FLK34-FLK34-2M0 HART Interface Cable 2 m 206084 HIACA-UNI-FLK34-FLK34-3M0 HART Interface Cable 3 m 208826 HIACA-UNI-FLK34-FLK34-6M0 HART Interface Cable 6 m HiD2000 Blank Empty housing Zener Barriers Z-System DC Barrier, Positive 71768 Z705 + 1 channel, 05V,10Ohm 71771 Z710 + 1 channel, 10V 50Ohm 071896 Z713 + 1 channel, 16V 22Ohm 71776 Z715 + 1 channel, 15V, 100Ohm 071781 Z715.1K + 1 channel,15V, 1kOhm 71784 Z722 + 1 channel,22V, 150 Ohm 71788 Z728 + 1 channel,28V, 300 Ohm 071790 Z728.CL 1 channel, 28V, 300 Ohm current limitation 071938 Z728.H + 1 channel, 28V 240 Ohm, high current 071792 Z755 + 2-channel, 05 V, 10 Ohm 71889 Z757 + 2-channel, 7,2 V, 10 Ohm 71796 Z764 + 2-channel, 12 V, 1 kOhm 71799 Z765 + 2-channel, 15 V, 100 Ohm 71802 Z772 + 2-channel, 22 V, 150 Ohm 71804 Z778 + 2-channel, 28 V, 600 Ohm 071806 Z779 + 2-channel, 28 V, 300 Ohm 71814 Z786 + 2-channel, 28 V, Diode 71816 Z787 + 2-channel, K1:28 V, 300 Ohm, K2:Diode 071940 Z787.H 2-channel, K1:28 V, 240 Ohm, K2:Diode, high current 71810 Z788 + 2-channel, K1:28 V, 300 Ohm, K2:10 V, 50 Ohm 71812 Z788.R + 2-channel, K1:28 V, 300 Ohm, K2:10 V, 50 Ohm, shunt resistor 802518 Z789 + 3-channel, K1: 2x 28 V, 300 Ohm, K2,K3: Diode 71808 Z796 + 2-channel, K1:26,6 V, 320 Ohm, K2:20,5 V, 415 Ohm DC Barrier, Positive, replaceable fuse 072183 Z715.F+ 1-channel, 15 V, 100 Ohm 072174 Z728.F+ 1-channel, 28 V, 300 Ohm 072175 Z728.H.F+ 1-channel, 28 V, 240 Ohm, high current 072184 Z765.F+ 2-channel, 15 V, 100 Ohm 072176 Z779.F+ 2-channel, 28 V, 300 Ohm 072177 Z779.H.F+ 2-channel, 28 V, 240 Ohm, high current 072178 Z787.F+ 2-channel, K1:28 V, 300 Ohm, K2:Diode 072179 Z787.H.F+ 2-channel, K1:28 V, 240 Ohm, K2:Diode, high current DC Barrier, Negative 71769 Z805 - 1-channel, 05 V, 10 Ohm 71772 Z810 - 1-channel, 10 V, 50 Ohm 71777 Z815 - 1-channel, 15 V, 100 Ohm 71785 Z822 - 1-channel, 22 V, 150 Ohm 71789 Z828 - 1-channel, 28 V, 300 Ohm 71890 Z857 - 2-channel, 7,2 V, 10 Ohm 71797 Z864 - 2-channel, 12 V, 1 kOhm 71800 Z865 - 2-channel, 15 V, 100 Ohm 71803 Z872 - 2-channel, 22 V, 150 Ohm 71805 Z878 - 2-channel, 28 V, 600 Ohm 71815 Z886 - 2-channel, 28 V, Diode 71817 Z887 - 2-channel, K1:28 V, 300 Ohm, K2:Diode 71811 Z888 - 2-channel, K1:28 V, 300 Ohm, K2:10 V, 50 Ohm 71813 Z888.R - 71809 Z896 - DC Barrier, Negative, replaceable fuse 072209 Z815.F- 1-channel, 15 V, 100 Ohm 072203 Z828.F- 1-channel, 28 V, 300 Ohm 072204 Z828.H.F- 1-channel, 28 V, 240 Ohm, high current 072210 Z865.F- 2-channel, 15 V, 100 Ohm 072205 Z879.F- 2-channel, 28 V, 300 Ohm 072206 Z879.H.F- 2-channel, 28 V, 240 Ohm, high current 072207 Z887.F- 2-channel, K1:28 V, 300 Ohm, K2:Diode 072208 Z887.H.F- 2-channel, K1:28 V, 240 Ohm, K2:Diode, high current AC Barrier 071770 Z905 a.c. 1-channel, 05 V, 10 Ohm 071773 Z910 a.c. 1-channel, 10 V, 50 Ohm 071778 Z915 a.c. 1-channel, 15 V, 100 Ohm 071783 Z915.1K a.c. 1-channel, 15 V, 1 kOhm 071891 Z922 a.c. 1-channel, 22 V, 150 Ohm 071857 Z928 a.c. 1-channel, 28 V, 300 Ohm 071863 Z954 a.c. 3-channel, 05 V, 10 Ohm 071794 Z955 a.c. 2-channel, 05 V, 10 Ohm 071858 Z960 a.c. 2-channel, 10 V, 50 Ohm 071795 Z961 a.c. 2-channel, 9 V, 100 Ohm 071798 Z964 a.c. 2-channel, 12 V, 1 kOhm 071859 Z965 a.c. 2-channel, 15 V, 100 Ohm 071801 Z966 a.c. 2-channel, 12 V, 150 Ohm 071860 Z967 a.c. 2-channel, 17 V, 120 Ohm 071861 Z972 a.c. 2-channel, 22 V, 300 Ohm 071862 Z978 a.c. 2-channel, 28 V, 600 Ohm AC Barrier, replaceable fuse 072180 Z960.F a.c. 2-channel, 10 V, 50 Ohm 072181 Z961.F a.c. 2-channel, 9 V, 100 Ohm 072182 Z966.F a.c. 2-channel, 12 V, 150 Ohm Accessories - Z-System 071818 Z799 Dummy 035846 ZH-ES/LB labelling strip, 25 labels 29mm x 8mm each 034391 ZH-Z.AB.NS mounting block 034389 ZH-Z.AK 16 connector 034388 ZH-Z.AK 4 connector 048595 ZH-Z.AR.125 spacer, set of 10 pieces 033212 ZH-Z.AR.200 spacer 033209 ZH-Z.BT label carrier 033208 ZH-Z.ES single socket 028782 ZH-Z.LL ground rail feed 034387 ZH-Z.NLS-CU 3/10 N-combined rail 034385 ZH-Z.USLKG 5 clamp